Cleveland-motion-controls Brake EMAG 4 Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 2
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
0 0,1 0,2 0,3 0,4 0,5
0
1
3
4
5
2
34
49
72
Ø
8h 07 Ø
39 Ø
041 Ø
35 Ø
2
5 E9
Ø 17 H8
31J 3
,91
39,5
+ 0,1
-0
Utilization
• Mounting must be made without any stress.
Lubricated for life (other internal lubrication not allowed).
The shaft should be lubricated upon assembly, to prevent seizing.
• Low DC current power supply for coil.
• The standard device is designed for horizontal shaft orientation,
and a minimal speed of 60 RPM. Maximum speed is 3000 RPM.
(without exceeding the max. heat dissipation capability)
• For Engineering application, please contact our technical support
• In normal use, the outside temperature of the device can increase up to 100°C,
without damage.
04 x 3M swercs 3
06 Ø
no °02
1
ta
mN eu
q
roT
Current A
Brake
EMAG 4H
Nominal torque 5 N.m ft.lbf 4
Minimal torque 0,1 N.m ft.lbf 0.07
Rated current DC A 0.50
Rotor inertia 99.10
-6
kg.m
2
lb.ft
2
23 10
-4
Weight 2 kg lb 4.41
Heat dissipation
W *
continuous sustained
100
Specifications
* Heat dissipation is the mechanical power (P = cw ) maximum allowable.
Coil resistance - 20°C Ohm 24
Cleveland Motion Controls, Inc.
7550 Hub Parkway
Cleveland, Ohio 44125
phone: 216.524.8800 or 800.321.8072
fax: 216.642.2199
www.cmccontrols.com
Vista de pagina 1
1 2

Comentarios a estos manuales

Sin comentarios