Cleveland-motion-controls ULTRA ISC SERIES SLIM CELL TRANSDUCER REV AA Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Cleveland-motion-controls ULTRA ISC SERIES SLIM CELL TRANSDUCER REV AA. Cleveland Motion Controls ULTRA ISC SERIES SLIM CELL TRANSDUCER REV AA User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - TRANSDUCER

INSTRUCTION MANUAL (MAN-70434-0) FOR ULTRA ISC SERIES SLIM CELL TRANSDUCER Cleveland Motion C

Pagina 2

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 1.2 FEATURES Ultra ISC tension transducer features are:  Factory Calibration promote

Pagina 3 - PAGE 3 OF 42

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 1.5 GENERAL SPECIFICATIONS Item Specification Comments Input Supply Power Supply Requir

Pagina 4

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 1.8 OPERATING CONDITIONS Condition Isolated Signal Conditioning Amplifier Installation

Pagina 5 - TABLE OF CONTENTS

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER Output Impedance Approximately 64 Ohms per Bridge leg Maximum Voltage, Gage to Beam or Bas

Pagina 6 - AGE 6 OF 42

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 1.13 BLOCK DIAGRAM OF ULTRA SERIES ISC AMPLIFIER MODULE Figure 2 Block Diagram of Ultra

Pagina 7 - FURTHER INFORMATION

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 2 PRODUCT COMPONENTS The Ultra Series ISC Slim Cell Tension Transducer (see Figure 3) consi

Pagina 8

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 2.1 M12 MATING CONNECTOR The M12 connector used on the Ultra Series ISC amplifier is a f

Pagina 9 - 1 PRODUCT OVERVIEW

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 2.2 ELECTRICAL CONNECTIONS AND WIRING Refer to Figure 5 for making the transducer to power

Pagina 10 - EMC RESPONSIBILITY

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 2.3 CABLING Important: Most start-up problems are the result of mis-wiring or failure to

Pagina 11 - NVIRONMENTAL REQUIREMENTS

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 2.4 POWER SUPPLY REQUIREMENTS For best performance, a regulated DC power supply that provi

Pagina 12 - PECIFICATIONS

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA REVISION HISTORY Rev ECO Author Date Description of Change AA XXX WGW As Release

Pagina 13 - 1.12 SLIM CELL FORCE RATINGS

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 2.5 POTENTIOMETERS ADJUSTMENTS (IF NEEDED) The gain and zero adjustments are factory pre

Pagina 14 - MAN-70434-0 REV AA

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 3 PRODUCT APPLICATION The Ultra Series Slim Cell Transducer utilizes a twin sensing beam.

Pagina 15 - 2 PRODUCT COMPONENTS

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 3.2 SUMMING In the majority of applications, loadcells are used in pairs. The net tensi

Pagina 16 - 2.1 M12 MATING CONNECTOR

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 3.3 SUMMING BY “SERIES STACKING” The final interface approach to be discussed is to “stack

Pagina 17 - PAGE 17 OF 42

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 4 INSTALLATION 4.1 RECEIVING AND UNPACKING After receiving the Ultra ISC Slim Cell Transd

Pagina 18 - 2.3 CABLING

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 4.2.2 MOUNTING HARDWARE AND RECOMMENDED FASTENER TORQUE UltraSlim 1: Torque: ¼ - 20 x 1-

Pagina 19 - 2.4.1 INTERFACE WIRING

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 4.2.3 MOUNTING DIMENSIONS 62 ° OF ANGULAR ALIGNMENTWITH BOLT IN POSITIONSLIM CELLMOUNTIN

Pagina 20

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER NC (3) NC (3) Z 2.50 3.30 NC (6) NC (6) Z 63.5 83.8 Table D Transducer and Mounting

Pagina 21 - SLIM CELL TRANSDUCERS

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA PAGE 28 OF 42 4.2.4 SELECTING A MOUNTING LOCATION Select the mounting location for the

Pagina 22 - 3.2 SUMMING

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 4.3 PRE-INSTALLATION PRECAUTIONS 4.3.1 SHIPPING Shock and vibration transmitted to the tran

Pagina 23 - LCHGAIN

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER WARRANTY AND LIMITATION OF LIABILITY All equipment is sold subject to the mutual agreement

Pagina 24 - 4 INSTALLATION

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 4.4 INSTALLATION PRECAUTIONS To ensure proper installation and operation of the system,

Pagina 25 - AGE 25 OF 42

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 4.6 POSITIONING THE SLIM CELL TRANSDUCER Use the following steps when positioning the tran

Pagina 26

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 4.7 MOUNTING THE SENSING ROLL Be sure to exercise care during this portion of the instal

Pagina 27 - AGE 27 OF 42

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 4.9 POWER-UP AND TESTING 4.9.1 BEFORE APPLYING POWER Before applying power, check the wiri

Pagina 28 - OK FOR TENSION SENSING

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 4.10 ADJUSTMENT TOOLS (ONLY IF NOT USING NUMERICAL CORRECTION) Using the correct tools s

Pagina 29 - 4.3.3 CRITICAL ROLL SPEED

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 4.12 PROPER PRACTICES FOR APPLYING CALIBRATION FORCES Seldom is a transducer oriented such

Pagina 30

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA Examples of Force Loss due to Friction at Driven Roll In this example, only a fraction of

Pagina 31 - PAGE 31 OF 42

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER  Always apply and remove the test load in a continuously increasing or decreasing manner,

Pagina 32

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 4.15 EMC CONNECTIONS AND INSTALLATION Compliance with the specified EMC directive for im

Pagina 33 - 4.9 POWER-UP AND TESTING

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 4.16 CABLE GLANDS Several manufacturers provide cable glands that can be used to ensure th

Pagina 34

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA PAGE 4 OF 42 BLANK

Pagina 35 - AGE 35 OF 42

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 5 TROUBLESHOOTING Do no let safety be an afterthought! Before installing, servicing or

Pagina 36

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 5.1 TRANSDUCER BENCH TESTING Because the strain gage signal conditioning is completely int

Pagina 37 - 4.14 FINAL CALIBRATION

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 6 MANUFACTURERS DECLARATION OF CONFORMITY Figure 13 EC Declaration of Conformity PAGE

Pagina 38

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER TABLE OF CONTENTS 1 PRODUCT OVERVIEW ...

Pagina 39 - 4.16 CABLE GLANDS

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA 4.10 ADJUSTMENT TOOLS (ONLY IF NOT USING NUMERICAL CORRECTION)...

Pagina 40 - 5 TROUBLESHOOTING

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER WARRANTY Cleveland Motion Controls warrants the goods against defects in design, material

Pagina 41 - 5.1 TRANSDUCER BENCH TESTING

ULTRA ISC SERIES SLIM CELL TRANSDUCER MAN-70434-0 REV AA PAGE 8 OF 42 BLANK

Pagina 42

MAN-70434-0 REV AA ULTRA ISC SERIES SLIM CELL TRANSDUCER 1 PRODUCT OVERVIEW 1.1 GENERAL DESCRIPTION The Ultra Series Integrated Signal Conditioning

Comentarios a estos manuales