AO-70174 12 Revision BA
WebPro Intermediate Tension Controller
Machine Parameters
From the Commissioning Menu; press 1 to show the Machine Parameters screen
Machine Parameters (SET UP = cancel)
changed
by using
default
value
Language English Deutsch Français Italiano Español
Unit system S.I. / Metric kgf / Pound/foot / Percent
Controller application Intermediate
Transducers before Before / After
or after main motor
Output trim only Yes / No
Output range +/- 2V / +/- 10V
Start in control screen No / Yes
Enable MAN/AUTO/OFF keys No / Yes
Dual tension range No / Yes
Full scale (low) Enter a value
Full scale (normal) Enter a value
Minimum tension 3% minimum, 20% maximum
Output level bias 20% maximum
Output level limit 100% maximum
Set point ramp rate 1% per second, 100% per second
Display damping time 0.1 seconds, 3 seconds
Display precision 0.1, 0.5, 1, 5, 10
Digital inputs
MACHINE START Disabled, 0V=OFF, 0V=ON
SELECT AUTO Disabled, 0V=OFF, 0V=ON
SELECT MANUAL Disabled, 0V=OFF, 0V=ON
SELECT OFF Disabled, 0V=OFF, 0V=ON
DIAMETER HOLD Disabled, 0V=OFF, 0V=ON
DIAMETER RESET Disabled, 0V=OFF, 0V=ON
BATCH HOLD Disabled, 0V=OFF, 0V=ON
ENABLE EXT SP Disabled, 0V=OFF, 0V=ON
Show internal calibration * No / Yes
Right transducer Disabled, Enabled
Line tacho or encoder * Disabled, Tacho, Encoder
+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-
numeric key
numeric key
numeric key
numeric key
numeric key
numeric key
numeric key
numeric key
+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-
+/-
English
S.I.
before
No
0-10V
No
No
No
5000N
5000N
6%
0%
100%
5%/sec
2 secs
1
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
No
Disabled
Disabled
An asterisk * indicates that a further menu will open if this item is selected.
Remember to press the CONFIRM key, otherwise the parameters will not be saved to the memory.
Note Start in Control Screen
The Controller is despatched with this item set to "No". We recommend that after all commissioning is
finished that this is then set to "Yes". When the Controller is now switched on, the program is loaded, the
company logos are shown briefly and then the Control or operating screen ready for use by the operator.
Note
The Controller will not accept an invalid input value which is outside the limits of operation. If an invalid
input is attempted the Controller will revert to the previous valid input.