ULTRA SERIES STATIONARY SHAFT TRANSDUCER TECHNICAL MANUAL MAN-70430-0 REV AA
4
1.8 Operating Conditions
Condition Isolated Signal Conditioning Amplifier
Installation category Category III
Pollution Pollution Degree 2
Input supply Earth (Ground) referenced
Protection Enclosure mounted
1.9 EMC Technical Ratings
Port Phenomenon Test Standard Level Test Standard
Enclosure ESD EN 61000-4-2: 8KV AD, 1KV CD EN 61326:1997
Enclosure RF Field EN 61000-4-3 10V/m,1 Khz AM EN 61326:1997
Transducer Leads
Fast Transient
Burst
EN 61000-4-4 1kV EN 61326:1997
Output Leads
Fast Transient
Burst
EN 61000-4-4 1kV EN 61326:1997
Transducer Leads
Conducted
Immunity
EN 61000-4-6 3V/m EN 61326:1997
Output Leads
Conducted
Immunity
EN 61000-4-6 3V/m EN 61326:1997
1.10 Emission specifications
Port Phenomenon Test Standard Level Generic Standard
Enclosure Radiated EN 61326:
1997
Class A EN 61326:1997
The levels of performance indicated are achieved when the Isolated Signal Conditioning Amplifier is
installed by using the instructions and specifications outlined in this document.