MAN-70430-0 REV AA ULTRA SERIES STATIONARY SHAFT TRANSDUCER TECHNICAL MANUAL
4.2.2 MOUNTING CONFIGURATIONS
Ultra Series Cartridge Transducers can be mounted on either the inside or outside of the machine frame
depending on the model type purchased (refer to Figure 10 and Table D). When choosing a mounting
confi
guration, evaluate your options by taking the following points into consideration:
Model type
Safety
Machine Frame orientation
Ease of Assembly
MACHINE FRAME
TYPE "S"
MOUNTING
TYPE "FL"
MOUNTING
SENSING ROLL SENSING ROLL
TYPE "PB"
MOUNTING
TYPE "BR"
MOUNTING
STATIONARY/DEAD SHAFTSTATIONARY/DEAD SHAFT
MACHINE FRAME
Figure 10– Types of Mounting Configurations
Table D – Mounting Type and Connector Compatibility
The Connector can be located
at:
When using this type of Mounting
Configuration:
End Side
Flange (FL)
X w/hole X
Stud (S)
X
Pillow Block (PB)
X
Bearing (BR)
X
The tension-sensing roll must not be located where the web wrap angle can vary, or the transducer will not
interpret the tension properly as the angle varies. If a variance in the wrap angle occurs, it is sensed by the
transducer as a tension change and the change is indicated on the tension indicator. In cases where it is
impossible to mount the transducer where the wrap angle does not vary, the change in indicated tension that
results should be calculated and if sufficiently small, can be disregarded.
WRAP VARIESWRAP VARIES
PROCESS
OK FOR TENSION SENSING
Figure 11 - Example of Varying Wrap Angles